Customized Cable for Charging Station Basic Info.Model NO.YJV32 YJV22Wire Core MaterialPure Annealed Soft CopperCertificationISO, CE, RoHS, VDEModelYjv32 Yjv22BrandQifanStandardIEC 60502-1 BS 5467Flame ResistantIEC 60332Staff3048QC206Transport PackageDrumSpecification1.5-800mm2TrademarkQifanOriginChinaHS Code8544492100Production Capacity20000km/MonthProduct Description600/1000V CU/XLPE/PVC/SWA/PVC Underground XLPE Cable Steel Wire Armoured SWA Cable Power Cable BS 5467 CU/XLPE/PVC/SWA/PVC Cable Selection It is essential that the type of cable ordered is suitable for its intended use. Cable choice will be based on a whole range of factors including installation specifications, relevant local regulations and the performance of appropriate cable types. It is therefore impossible to provide a conclusive guide to cable selection and we would advise you to contact us for our specialist advice on suitable designs to meet you specific cable needs. Cable structure Conductors Conductors shall be of Copper or Aluminium, circular standed(Non-compacted or Compacted) or Shaped, Class 1 or Class 2 to IEC 60228, BS EN 60228. For smaller sizes, a solid circular conductor, Class 1 as per IEC 60228, BS EN 60228 can also be supplied upon request. Insulation XLPE material and thickness shall be as per IEC 60502-1 or BS 5467 rated for 90掳 C continuous operation. PVC material and thickness shall be as per IEC 60502-1 or BS 6346. PVC insulation Material-PVC/A as per IEC 60502 or TI1 as per BS EN 50363. PVC insulation as per SASO 1694 rated for 85掳 C continuous operation is also available on request. Assembly Two, Three Four or Five insulated conductors are laid-up together with non-hygroscopic fillers compatible with the insulation material. Inner sheath The assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted if the outer shape of the cable remains practically circular. Armour Galvanized Steel Wires applied helically over the bedding as per IEC 60502-1 or as per BS 5467, BS 6346. (Single core cables shall be Aluminium wire armoured)(SWA/AWA) Double Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502-1.(STA) Outer Sheath Outer sheath will be extruded PVC/ST2 as per IEC 60502-1, Type 9 as per BS 7655. Special type of PVC sheathing material such as fire retardant PVC, anti-termite and anti-rodent PVC, ultraviolet PVC, Oil resistant PVC, etc. Are available on request also other special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE etc are available. Flame Performance of Cable Sheaths Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or other equivalent standards. Standard: IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer Type and Name: TypeDesignationApplications VVCopper conductor, PVC insulated, PVC sheathed power cableFor laying indoors, in tunnel or cable trench, unable to bear external mechanical forces .Single core cable is not allowed to lay in a magnetic duct. VLVAluminum conductor, PVC insulated, PVC sheathed power cable VYCopper conductor, PVC insulated, PE sheathed power cable VLYAluminum conductor, PVC insulated, PE sheathed power cable VV22Copper conductor, PVC insulated, steel tape armored, PVC sheathed power cableFor laying indoors, in a tunnel in cable trench, or direct in ground, able to bear external mechanical forces. The single-core cable is not allowed to lay in the magnetic duct. VLV22Aluminum conductor, PVC insulated, steel tape armored, PVC sheathed power cable VV23Copper conductor, PVC insulated, steel tape armored, PE sheathed power cable VLV23Aluminum conductor, PVC insulated, steel tape armored, PE sheathed power cable VV32Copper conductor, PVC insulated, steel wire armored, PVC sheathed power cableFor laying indoors, in tunnel cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force. VLV32Aluminum conductor, PVC insulated, steel wire armored, PVC sheathed power cable VV33Copper conductor, PVC insulated, steel wire armored, PE sheathed power cable VLV33Aluminum conductor, PVC insulated, steel wire armored, PE sheathed power cable Type and Name: TypeDesignationApplications YJVCopper conductor, XLPE insulated, PVC sheathed power cableFor laying indoors, in tunnel or cable trench, unable to bear external mechanical forces .Single core cable is not allowed to lay in a magnetic duct. YJLVAluminum conductor,XLPE insulated, PVC sheathed power cable YJYCopper conductor, XLPE insulated, PE sheathed power cable YJJLYAluminum conductor, XLPE insulated, PE sheathed power cable YJV22Copper conductor,XLPE insulated, steel tape armored, PVC sheathed power cableFor laying indoors, in a tunnel in cable trench, or direct in ground, able to bear external mechanical forces. The single-core cable is not allowed to lay in the magnetic duct. YJLV22Aluminum conductor, XLPE insulated, steel tape armored, PVC sheathed power cable YJV23Copper conductor, XLPE insulated, steel tape armored, PE sheathed power cable YJLV23Aluminum conductor, XLPE insulated, steel tape armored, PE sheathed power cable YJV32Copper conductor, XLPE insulated, steel wire armored, PVC sheathed power cableFor laying indoors, in tunnel cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force. YJLV32Aluminum conductor, XLPE insulated, steel wire armored, PVC sheathed power cable YJV33Copper conductor, XLPE insulated, steel wire armored, PE sheathed power cable YJLV33Aluminum conductor, XLPE insulated, steel wire armored, PE sheathed power cable Cable Technical data sheet No. x mm2PhaseNeutral/EarthInner sheathArmoredOuter sheathWeight of Cable Diameter of conductor mmThickness of XLPE mmDiameter of conductor mmThickness of XLPE mmThickness mmDiameter of wire mmThickness of Sheath mmComplete Diameter mmYJV32(CU) kg/kmYJLV32(AL) kg/km 4*1.51.380.7--10.81.814.3391.3353.7 4*2.51.780.7--10.81.815.3459.7397.2 4*42.250.7--10.81.816.4551.7451.8 4*62.760.7--11.251.818.6800.7650.4 4*1040.7--11.251.821.61089.3837.6 4*165.10.7--11.61.824.915431151.1 4*256.30.9--11.61.828.82094.71481.8 4*356.20.9--11.61.92723861531.9 4*507.61--11.6230.73014.11858.5 4*708.81.1--1.222.235.44298.92603.3 4*9510.51.1--1.222.339.35480.43149.3 4*12011.21.2--1.42.52.543.16972.24033.1 4*150131.4--1.42.52.648.28452.24784.6 4*18514.51.6--1.62.52.853.110276.85704.9 4*24016.21.7--1.62.5357.712650.16721.6 4*300191.8--1.62.53.264.715397.17986.5 5*1.51.380.71.380.710.81.815.1431384 5*2.51.780.71.780.710.81.816.2518.9440.7 5*42.250.72.250.711.251.818.4762.6637.7 5*62.760.72.760.711.251.819.7909.8722 5*1040.740.711.251.823.11245.8931.2 5*165.10.75.10.711.61.826.81797.51307.6 5*256.30.96.30.911.61.831.12444.21678 5*3570.970.911.61.933.22988.71921.1 5*508.218.211.222.138.54106.22661.7 5*705.11.1101.11.222.338.251293009.5 5*956.21.111.61.11.42.52.443.66956.44042.5 5*1206.61.2131.21.42.52.646.88317.74643.9 5*1507.61.414.61.41.62.52.852.410163.55579 5*1858.51.616.21.61.62.5357.412320.86605.8 5*2409.61.718.41.71.62.53.262.815266.77856.1 5*30010.81.820.61.81.83.153.470.119366.510103.3 3*2.5+1*1.51.780.71.380.710.81.815.1442.9386.6 3*4+1*2.52.250.71.780.710.81.816.1527.8437.3 3*6+1*42.760.72.250.711.251.818.3776.2638.6 3*10+1*640.72.760.711.251.820.81014787.7 3*16+1*105.10.740.711.251.823.61322.2965.4 3*25+1*166.30.95.10.711.61.827.81953.61395.9 3*35+1*166.70.95.10.711.61.828.82295.11556.6 3*50+1*257.416.30.911.61.931.12847.61827.7 3*70+1*358.71.170.91.222.136.24015.52530.3 3*95+1*5010.51.18.211.222.240.55076.73039.4 3*120+1*7011.61.2101.11.222.443.96227.13598.8 3*150+1*70131.4101.11.42.52.549.77816.54641.9 3*185+1*9514.51.611.61.11.42.52.754.59503.85492.1 3*240+1*12016.51.7131.21.62.52.960.411746.46565.3 3*300+1*15018.81.814.61.41.62.5366.3141267651.2 3*2.5+2*1.51.780.71.380.710.81.815.8484.5418.8 3*4+2*2.52.250.71.780.711.251.817.8702.1596 3*6+2*42.760.72.250.711.251.819.2853.3690.7 3*10+2*640.72.760.711.251.821.71110846.1 3*16+2*105.10.740.711.61.825.61635.81216.1 3*25+2*166.30.95.10.711.61.829.32182.11526.4 3*35+2*166.50.95.10.711.61.829.12453.21616.7 3*50+2*257.416.30.911.6232.23125.61952.5 3*70+2*3591.170.91.222.137.94482.42783.7 3*95+2*5010.71.18.211.222.342.45679.23353.1 3*120+2*70121.2101.11.42.52.547.87499.74447.5 3*150+2*7013.41.4101.11.42.52.652.38649.75051.2 3*185+2*95151.611.61.11.62.52.857.910681.16086.6 3*240+2*120171.7131.21.62.5363.613074.77158.8 3*300+2*15019.21.814.61.41.62.53.269.715769.38377.6 Note: Galvanized Steel Wires applied helically over the bedding as per IEC 60502-1 or as per BS 5467, BS 6346. Single core cables shall be Aluminium wire armoured) Customized Cable for Charging Station website:http://www.qifandianlan.net/cable-for-charging-station/
Search
Popular Posts
- С легкостью заказываем документы в онлайн магазине Russian Diplom
-
Stair Lifts and Climbing Devices Market Size, Key Market Players, SWOT, Revenue Growth Analysis, 2023–2032
By Adams mark
- Что необходимо из оборудования для изготовления документов?
- Советы эксперта, что позволят легко приобрести диплом
- Получите диплом без лишних забот и усилий